164
960H 2U series product interface is shown as in Figure 3-15.
Figure 3-15
You can refer to the following sheet for alarm input and output information.
1234,, 5, 6, 7,
8, 9, 10, 11, 12, 13,
14, 15, 16
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
NO1 C1
NO2 C2
NO3 C3
NO4 C4,
NO5 C5 NC5
The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
CTRL 12V Control power output. The power output is off when the alarm is
canceled.
+12V It is rated power output.
Earth cable.
T+, T-, R+, R-
4-pin full-duplex RS485 port. T+T- are the output cable and R+
R- are input cable.
485 A/B 485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120T between A/B cables if there are
too many PTZ decoders.
3.8.1.15 8HDD Full-D1 2U Entry-level Series
The 8HDD full-D1 2U entry-level series product interface is shown as in Figure 3-16.
Figure 3-16
You can refer to the following sheet for detailed information
12345
678910
11121314
1516
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
1-NO C2-NO C
3-NO C
There are three groups of normal open activation output (on/off
button).
Earth cable.
3.8.2 Alarm Input Port
Please refer to the following sheet for more information.
Normal open or Normal close type.
Please parallel connect COM end and GND end of the alarm detector (Provide external
power to the alarm detector).
Please parallel connect the Ground of the DVR and the ground of the alarm detector.